The Reliability of a Three-Dimensional Photo System- (3dMDface-)‎ Based Evaluation of the Face in Cleft Lip Infants

Joint Authors

Matthews, Felix
Grätz, Klaus W.
Metzler, Philipp
Ort, Rebecca
Luebbers, Heinz-Theo
Zemann, Wolfgang
Kruse, Astrid L.

Source

Plastic Surgery International

Issue

Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-8, 8 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2012-08-05

Country of Publication

Egypt

No. of Pages

8

Main Subjects

Medicine

Abstract EN

Ample data exists about the high precision of three-dimensional (3D) scanning devices and their data acquisition of the facial surface.

However, a question remains regarding which facial landmarks are reliable if identified in 3D images taken under clinical circumstances.

Sources of error to be addressed could be technical, user dependent, or patient respectively anatomy related.

Based on clinical 3D photos taken with the 3dMDface system, the intra observer repeatability of 27 facial landmarks in six cleft lip (CL) infants and one non-CL infant was evaluated based on a total of over 1,100 measurements.

Data acquisition was sometimes challenging but successful in all patients.

The mean error was 0.86 mm, with a range of 0.39 mm (Exocanthion) to 2.21 mm (soft gonion).

Typically, landmarks provided a small mean error but still showed quite a high variance in measurements, for example, exocanthion from 0.04 mm to 0.93 mm.

Vice versa, relatively imprecise landmarks still provide accurate data regarding specific spatial planes.

One must be aware of the fact that the degree of precision is dependent on landmarks and spatial planes in question.

In clinical investigations, the degree of reliability for landmarks evaluated should be taken into account.

Additional reliability can be achieved via multiple measuring.

American Psychological Association (APA)

Ort, Rebecca& Metzler, Philipp& Kruse, Astrid L.& Matthews, Felix& Zemann, Wolfgang& Grätz, Klaus W.…[et al.]. 2012. The Reliability of a Three-Dimensional Photo System- (3dMDface-) Based Evaluation of the Face in Cleft Lip Infants. Plastic Surgery International،Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-448717

Modern Language Association (MLA)

Ort, Rebecca…[et al.]. The Reliability of a Three-Dimensional Photo System- (3dMDface-) Based Evaluation of the Face in Cleft Lip Infants. Plastic Surgery International No. 2012 (2012), pp.1-8.
https://search.emarefa.net/detail/BIM-448717

American Medical Association (AMA)

Ort, Rebecca& Metzler, Philipp& Kruse, Astrid L.& Matthews, Felix& Zemann, Wolfgang& Grätz, Klaus W.…[et al.]. The Reliability of a Three-Dimensional Photo System- (3dMDface-) Based Evaluation of the Face in Cleft Lip Infants. Plastic Surgery International. 2012. Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-448717

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-448717