Spatiotemporal Quantification of Local Drug Delivery Using MRI
المؤلفون المشاركون
Giers, Morgan B.
Caplan, Michael R.
Frakes, David
Plasencia, Jonathan D.
McLemore, Ryan
McLaren, Alex C.
المصدر
Computational and Mathematical Methods in Medicine
العدد
المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-12، 12ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2013-04-24
دولة النشر
مصر
عدد الصفحات
12
التخصصات الرئيسية
الملخص EN
Controlled release formulations for local, in vivo drug delivery are of growing interest to device manufacturers, research scientists, and clinicians; however, most research characterizing controlled release formulations occurs in vitro because the spatial and temporal distribution of drug delivery is difficult to measure in vivo.
In this work, in vivo magnetic resonance imaging (MRI) of local drug delivery was performed to visualize and quantify the time resolved distribution of MRI contrast agents.
Three-dimensional T1 maps (generated from T1-weighted images with varied TR) were processed using noise-reducing filtering.
A segmented region of contrast, from a thresholded image, was converted to concentration maps using the equation 1/T1=1/T1,0+R1C, where T1,0 and T1 are the precontrast and postcontrast T1 map values, respectively.
In this technique, a uniform estimated value for T1,0 was used.
Error estimations were performed for each step.
The practical usefulness of this method was assessed using comparisons between devices located in different locations both with and without contrast.
The method using a uniform T1,0, requiring no registration of pre- and postcontrast image volumes, was compared to a method using either affine or deformation registrations.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Giers, Morgan B.& McLaren, Alex C.& Plasencia, Jonathan D.& Frakes, David& McLemore, Ryan& Caplan, Michael R.. 2013. Spatiotemporal Quantification of Local Drug Delivery Using MRI. Computational and Mathematical Methods in Medicine،Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-449717
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Giers, Morgan B.…[et al.]. Spatiotemporal Quantification of Local Drug Delivery Using MRI. Computational and Mathematical Methods in Medicine No. 2013 (2013), pp.1-12.
https://search.emarefa.net/detail/BIM-449717
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Giers, Morgan B.& McLaren, Alex C.& Plasencia, Jonathan D.& Frakes, David& McLemore, Ryan& Caplan, Michael R.. Spatiotemporal Quantification of Local Drug Delivery Using MRI. Computational and Mathematical Methods in Medicine. 2013. Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-449717
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-449717
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر