Quantitative Accuracy of Low-Count SPECT Imaging in Phantom and In Vivo Mouse Studies
المؤلفون المشاركون
Sosabowski, Jane K.
Mather, Stephen J.
Foster, Julie M.
Murray, Iain
Finucane, Ciara M.
المصدر
International Journal of Molecular Imaging
العدد
المجلد 2011، العدد 2011 (31 ديسمبر/كانون الأول 2011)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2011-03-16
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
We investigated the accuracy of a single photon emission computed tomography (SPECT) system in quantifying a wide range of radioactivity concentrations using different scan times in both phantom and animal models.
A phantom containing various amounts of In-111 or Tc-99m was imaged until the activity had decayed close to background levels.
Scans were acquired for different durations, employing different collimator pinhole sizes.
VOI analysis was performed to quantify uptake in the images and the values compared to the true activity.
The phantom results were then validated in tumour-bearing mice.
The use of an appropriate calibration phantom and disabling of a background subtraction feature meant that absolute errors were within 12% of the true activity.
Furthermore, a comparison of in vivo imaging and biodistribution studies in mice showed a correlation of 0.99 for activities over the 200 kBq to 5 MBq range.
We conclude that the quantitative information provided by the NanoSPECT camera is accurate and allows replacement of dissection studies for assessment of radiotracer biodistribution in mouse models.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Finucane, Ciara M.& Murray, Iain& Sosabowski, Jane K.& Foster, Julie M.& Mather, Stephen J.. 2011. Quantitative Accuracy of Low-Count SPECT Imaging in Phantom and In Vivo Mouse Studies. International Journal of Molecular Imaging،Vol. 2011, no. 2011, pp.1-8.
https://search.emarefa.net/detail/BIM-453788
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Finucane, Ciara M.…[et al.]. Quantitative Accuracy of Low-Count SPECT Imaging in Phantom and In Vivo Mouse Studies. International Journal of Molecular Imaging No. 2011 (2011), pp.1-8.
https://search.emarefa.net/detail/BIM-453788
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Finucane, Ciara M.& Murray, Iain& Sosabowski, Jane K.& Foster, Julie M.& Mather, Stephen J.. Quantitative Accuracy of Low-Count SPECT Imaging in Phantom and In Vivo Mouse Studies. International Journal of Molecular Imaging. 2011. Vol. 2011, no. 2011, pp.1-8.
https://search.emarefa.net/detail/BIM-453788
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-453788
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر