Fetal ECG Extraction from Abdominal Signals : A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics

المؤلفون المشاركون

Ungureanu, Georgeta-Mihaela
Ţarălungă, Dragoş-Daniel
Wolf, Werner
Gussi, Ilinca
Strungaru, Rodica

المصدر

Computational and Mathematical Methods in Medicine

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-15، 15ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-02-09

دولة النشر

مصر

عدد الصفحات

15

التخصصات الرئيسية

الطب البشري

الملخص EN

Interference of power line (PLI) (fundamental frequency and its harmonics) is usually present in biopotential measurements.

Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG), electroencephalograms (EEG), and electrocardiograms (ECG).

When analyzing the fetal ECG (fECG) recorded on the maternal abdomen, the PLI represents a particular strong noise component, being sometimes 10 times greater than the fECG signal, and thus impairing the extraction of any useful information regarding the fetal health state.

Many signal processing methods for cancelling the PLI from biopotentials are available in the literature.

In this review study, six different principles are analyzed and discussed, and their performance is evaluated on simulated data (three different scenarios), based on five quantitative performance indices.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Ţarălungă, Dragoş-Daniel& Ungureanu, Georgeta-Mihaela& Gussi, Ilinca& Strungaru, Rodica& Wolf, Werner. 2014. Fetal ECG Extraction from Abdominal Signals : A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics. Computational and Mathematical Methods in Medicine،Vol. 2014, no. 2014, pp.1-15.
https://search.emarefa.net/detail/BIM-456413

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Ţarălungă, Dragoş-Daniel…[et al.]. Fetal ECG Extraction from Abdominal Signals : A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics. Computational and Mathematical Methods in Medicine No. 2014 (2014), pp.1-15.
https://search.emarefa.net/detail/BIM-456413

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Ţarălungă, Dragoş-Daniel& Ungureanu, Georgeta-Mihaela& Gussi, Ilinca& Strungaru, Rodica& Wolf, Werner. Fetal ECG Extraction from Abdominal Signals : A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics. Computational and Mathematical Methods in Medicine. 2014. Vol. 2014, no. 2014, pp.1-15.
https://search.emarefa.net/detail/BIM-456413

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-456413