Fetal ECG Extraction from Abdominal Signals : A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics

Joint Authors

Ungureanu, Georgeta-Mihaela
Ţarălungă, Dragoş-Daniel
Wolf, Werner
Gussi, Ilinca
Strungaru, Rodica

Source

Computational and Mathematical Methods in Medicine

Issue

Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-15, 15 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2014-02-09

Country of Publication

Egypt

No. of Pages

15

Main Subjects

Medicine

Abstract EN

Interference of power line (PLI) (fundamental frequency and its harmonics) is usually present in biopotential measurements.

Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG), electroencephalograms (EEG), and electrocardiograms (ECG).

When analyzing the fetal ECG (fECG) recorded on the maternal abdomen, the PLI represents a particular strong noise component, being sometimes 10 times greater than the fECG signal, and thus impairing the extraction of any useful information regarding the fetal health state.

Many signal processing methods for cancelling the PLI from biopotentials are available in the literature.

In this review study, six different principles are analyzed and discussed, and their performance is evaluated on simulated data (three different scenarios), based on five quantitative performance indices.

American Psychological Association (APA)

Ţarălungă, Dragoş-Daniel& Ungureanu, Georgeta-Mihaela& Gussi, Ilinca& Strungaru, Rodica& Wolf, Werner. 2014. Fetal ECG Extraction from Abdominal Signals : A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics. Computational and Mathematical Methods in Medicine،Vol. 2014, no. 2014, pp.1-15.
https://search.emarefa.net/detail/BIM-456413

Modern Language Association (MLA)

Ţarălungă, Dragoş-Daniel…[et al.]. Fetal ECG Extraction from Abdominal Signals : A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics. Computational and Mathematical Methods in Medicine No. 2014 (2014), pp.1-15.
https://search.emarefa.net/detail/BIM-456413

American Medical Association (AMA)

Ţarălungă, Dragoş-Daniel& Ungureanu, Georgeta-Mihaela& Gussi, Ilinca& Strungaru, Rodica& Wolf, Werner. Fetal ECG Extraction from Abdominal Signals : A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics. Computational and Mathematical Methods in Medicine. 2014. Vol. 2014, no. 2014, pp.1-15.
https://search.emarefa.net/detail/BIM-456413

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-456413