![](/images/graphics-bg.png)
Fetal ECG Extraction from Abdominal Signals : A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics
Joint Authors
Ungureanu, Georgeta-Mihaela
Ţarălungă, Dragoş-Daniel
Wolf, Werner
Gussi, Ilinca
Strungaru, Rodica
Source
Computational and Mathematical Methods in Medicine
Issue
Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-15, 15 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2014-02-09
Country of Publication
Egypt
No. of Pages
15
Main Subjects
Abstract EN
Interference of power line (PLI) (fundamental frequency and its harmonics) is usually present in biopotential measurements.
Despite all countermeasures, the PLI still corrupts physiological signals, for example, electromyograms (EMG), electroencephalograms (EEG), and electrocardiograms (ECG).
When analyzing the fetal ECG (fECG) recorded on the maternal abdomen, the PLI represents a particular strong noise component, being sometimes 10 times greater than the fECG signal, and thus impairing the extraction of any useful information regarding the fetal health state.
Many signal processing methods for cancelling the PLI from biopotentials are available in the literature.
In this review study, six different principles are analyzed and discussed, and their performance is evaluated on simulated data (three different scenarios), based on five quantitative performance indices.
American Psychological Association (APA)
Ţarălungă, Dragoş-Daniel& Ungureanu, Georgeta-Mihaela& Gussi, Ilinca& Strungaru, Rodica& Wolf, Werner. 2014. Fetal ECG Extraction from Abdominal Signals : A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics. Computational and Mathematical Methods in Medicine،Vol. 2014, no. 2014, pp.1-15.
https://search.emarefa.net/detail/BIM-456413
Modern Language Association (MLA)
Ţarălungă, Dragoş-Daniel…[et al.]. Fetal ECG Extraction from Abdominal Signals : A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics. Computational and Mathematical Methods in Medicine No. 2014 (2014), pp.1-15.
https://search.emarefa.net/detail/BIM-456413
American Medical Association (AMA)
Ţarălungă, Dragoş-Daniel& Ungureanu, Georgeta-Mihaela& Gussi, Ilinca& Strungaru, Rodica& Wolf, Werner. Fetal ECG Extraction from Abdominal Signals : A Review on Suppression of Fundamental Power Line Interference Component and Its Harmonics. Computational and Mathematical Methods in Medicine. 2014. Vol. 2014, no. 2014, pp.1-15.
https://search.emarefa.net/detail/BIM-456413
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-456413