الملخص EN
Novel bimetallic nanoparticles have been synthesized via rapid microwave irradiation, leading to an improved sensitivity and a highly anti-interference property for amperometric biosensor in H2O2 detection.
The material characterizations were performed by TEM, XRD, and EDX, which show the bimetallic formation of Pt-based catalysts and well-dispersed nanoparticles of 2–5 nm.
The sensitivities for the detection of H2O2 of PtRu, PtAu, and PtIr as the biosensor working electrode catalysts are 539.01 (R2=0.99), 415.46 (R2=0.99), and 404.52 (R2=0.97) μA⋅mM−1⋅cm-2, respectively, nearly twice higher than the pure Pt catalyst (221.77 μA⋅mM−1⋅cm−2, R2=0.98), at a low applied potential of +0.25 V versus Ag/AgCl.
Furthermore, Pt-Ru and Pt-Ir show a highly sensitive response and a promising anti-interference capability to ascorbic acid, a major interferent, by reducing the interferent current as low as 7-8% significantly lower than that of Pt (30% change).
The enhancement of both sensitivity and selectivity in the bimetallic catalysts can be found practical applications in biosensing.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Zhang, Yuan& Janyasupab, Metini& Liu, Chen-Wei& Lin, Po-Yuan& Wang, Kuan-Wen& Xu, Jiaqiang…[et al.]. 2012. Improvement of Amperometric Biosensor Performance for H2O2 Detection based on Bimetallic PtM (M = Ru, Au, and Ir) Nanoparticles. International Journal of Electrochemistry،Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-469995
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Zhang, Yuan…[et al.]. Improvement of Amperometric Biosensor Performance for H2O2 Detection based on Bimetallic PtM (M = Ru, Au, and Ir) Nanoparticles. International Journal of Electrochemistry No. 2012 (2012), pp.1-8.
https://search.emarefa.net/detail/BIM-469995
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Zhang, Yuan& Janyasupab, Metini& Liu, Chen-Wei& Lin, Po-Yuan& Wang, Kuan-Wen& Xu, Jiaqiang…[et al.]. Improvement of Amperometric Biosensor Performance for H2O2 Detection based on Bimetallic PtM (M = Ru, Au, and Ir) Nanoparticles. International Journal of Electrochemistry. 2012. Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-469995
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-469995
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)