Improvement of Amperometric Biosensor Performance for H2O2 Detection based on Bimetallic PtM (M = Ru, Au, and Ir)‎ Nanoparticles

Joint Authors

Liu, Chung-Chiun
Lin, Po-Yuan
Liu, Chen-Wei
Zhang, Yuan
Xu, Jiaqiang
Wang, Kuan-Wen
Janyasupab, Metini

Source

International Journal of Electrochemistry

Issue

Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-8, 8 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2012-02-08

Country of Publication

Egypt

No. of Pages

8

Main Subjects

Chemistry

Abstract EN

Novel bimetallic nanoparticles have been synthesized via rapid microwave irradiation, leading to an improved sensitivity and a highly anti-interference property for amperometric biosensor in H2O2 detection.

The material characterizations were performed by TEM, XRD, and EDX, which show the bimetallic formation of Pt-based catalysts and well-dispersed nanoparticles of 2–5 nm.

The sensitivities for the detection of H2O2 of PtRu, PtAu, and PtIr as the biosensor working electrode catalysts are 539.01 (R2=0.99), 415.46 (R2=0.99), and 404.52 (R2=0.97) μA⋅mM−1⋅cm-2, respectively, nearly twice higher than the pure Pt catalyst (221.77 μA⋅mM−1⋅cm−2, R2=0.98), at a low applied potential of +0.25 V versus Ag/AgCl.

Furthermore, Pt-Ru and Pt-Ir show a highly sensitive response and a promising anti-interference capability to ascorbic acid, a major interferent, by reducing the interferent current as low as 7-8% significantly lower than that of Pt (30% change).

The enhancement of both sensitivity and selectivity in the bimetallic catalysts can be found practical applications in biosensing.

American Psychological Association (APA)

Zhang, Yuan& Janyasupab, Metini& Liu, Chen-Wei& Lin, Po-Yuan& Wang, Kuan-Wen& Xu, Jiaqiang…[et al.]. 2012. Improvement of Amperometric Biosensor Performance for H2O2 Detection based on Bimetallic PtM (M = Ru, Au, and Ir) Nanoparticles. International Journal of Electrochemistry،Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-469995

Modern Language Association (MLA)

Zhang, Yuan…[et al.]. Improvement of Amperometric Biosensor Performance for H2O2 Detection based on Bimetallic PtM (M = Ru, Au, and Ir) Nanoparticles. International Journal of Electrochemistry No. 2012 (2012), pp.1-8.
https://search.emarefa.net/detail/BIM-469995

American Medical Association (AMA)

Zhang, Yuan& Janyasupab, Metini& Liu, Chen-Wei& Lin, Po-Yuan& Wang, Kuan-Wen& Xu, Jiaqiang…[et al.]. Improvement of Amperometric Biosensor Performance for H2O2 Detection based on Bimetallic PtM (M = Ru, Au, and Ir) Nanoparticles. International Journal of Electrochemistry. 2012. Vol. 2012, no. 2012, pp.1-8.
https://search.emarefa.net/detail/BIM-469995

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-469995