Research on the Energy Consumption Evaluation and Energy Saving Technical Reconstruction of Centrifugal Pump System Based on Actual Demand
المؤلفون المشاركون
Yuan, Shouqi
Yin, Luo
Yuan, Jianping
Yue, Tang
المصدر
Advances in Mechanical Engineering
العدد
المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-12، 12ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2013-12-29
دولة النشر
مصر
عدد الصفحات
12
التخصصات الرئيسية
الملخص EN
A new method for calculating the operational efficiency of a pumping station has been developed based on the integral principle and operation rules of the pump flow rate.
To determine the energy saving space of a pumping system and to reflect the relationship between supply and demand, a new method for evaluating the energy consumption rate of a pump system has been developed based on the principle of an inverter-controlled water supply with varying pressures.
These methods have been applied to a pump station with an apparently efficient operation.
By evaluating energy consumption based on actual demand, we developed a new strategy that configures a single frequency converter with a small transitional pump and decreases the energy consumption by almost 14% with a payback time of less than three years.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Yin, Luo& Yuan, Shouqi& Yue, Tang& Yuan, Jianping. 2013. Research on the Energy Consumption Evaluation and Energy Saving Technical Reconstruction of Centrifugal Pump System Based on Actual Demand. Advances in Mechanical Engineering،Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-470981
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Yin, Luo…[et al.]. Research on the Energy Consumption Evaluation and Energy Saving Technical Reconstruction of Centrifugal Pump System Based on Actual Demand. Advances in Mechanical Engineering No. 2013 (2013), pp.1-12.
https://search.emarefa.net/detail/BIM-470981
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Yin, Luo& Yuan, Shouqi& Yue, Tang& Yuan, Jianping. Research on the Energy Consumption Evaluation and Energy Saving Technical Reconstruction of Centrifugal Pump System Based on Actual Demand. Advances in Mechanical Engineering. 2013. Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-470981
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-470981
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر