![](/images/graphics-bg.png)
Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression
المؤلفون المشاركون
Matsumoto, Celso Soiti
Mizota, Atsushi
Shinoda, Kei
Matsumoto, Harue
Terauchi, Gaku
المصدر
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-5، 5ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-03-27
دولة النشر
مصر
عدد الصفحات
5
التخصصات الرئيسية
الملخص EN
The effect of the diameter of an intraocular lens (IOL) implanted in enucleated porcine eyes on the intraocular pressure induced by scleral depression was investigated.
Two IOLs of 6 mm and 7 mm optic diameter were implanted.
The intraocular pressure (IOP) was monitored during scleral depression by a transducer placed in the midvitreous through a sclerotomy at 6 o’clock.
The area under the curve (AUC) of the IOP changes from the beginning of the indentation to the point when the peripheral retinal surface was observed through the IOL optics was measured.
The AUC was significantly larger in eyes with a 6 mm IOL than in eyes with a 7 mm IOL (p<0.05).
The IOP elevation at the endpoint was higher in eyes with the 6 mm IOL than in eyes with the 7 mm IOL.
We conclude that the AUC may represent the degree of stress induced by scleral depression.
The higher AUC value with the X-60 may be because of the longer distance from the peripheral retina to the edge of the IOL optics.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Terauchi, Gaku& Matsumoto, Celso Soiti& Shinoda, Kei& Matsumoto, Harue& Mizota, Atsushi. 2014. Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression. BioMed Research International،Vol. 2014, no. 2014, pp.1-5.
https://search.emarefa.net/detail/BIM-482899
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Terauchi, Gaku…[et al.]. Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression. BioMed Research International No. 2014 (2014), pp.1-5.
https://search.emarefa.net/detail/BIM-482899
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Terauchi, Gaku& Matsumoto, Celso Soiti& Shinoda, Kei& Matsumoto, Harue& Mizota, Atsushi. Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-5.
https://search.emarefa.net/detail/BIM-482899
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-482899
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)