![](/images/graphics-bg.png)
Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression
Joint Authors
Matsumoto, Celso Soiti
Mizota, Atsushi
Shinoda, Kei
Matsumoto, Harue
Terauchi, Gaku
Source
Issue
Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-5, 5 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2014-03-27
Country of Publication
Egypt
No. of Pages
5
Main Subjects
Abstract EN
The effect of the diameter of an intraocular lens (IOL) implanted in enucleated porcine eyes on the intraocular pressure induced by scleral depression was investigated.
Two IOLs of 6 mm and 7 mm optic diameter were implanted.
The intraocular pressure (IOP) was monitored during scleral depression by a transducer placed in the midvitreous through a sclerotomy at 6 o’clock.
The area under the curve (AUC) of the IOP changes from the beginning of the indentation to the point when the peripheral retinal surface was observed through the IOL optics was measured.
The AUC was significantly larger in eyes with a 6 mm IOL than in eyes with a 7 mm IOL (p<0.05).
The IOP elevation at the endpoint was higher in eyes with the 6 mm IOL than in eyes with the 7 mm IOL.
We conclude that the AUC may represent the degree of stress induced by scleral depression.
The higher AUC value with the X-60 may be because of the longer distance from the peripheral retina to the edge of the IOL optics.
American Psychological Association (APA)
Terauchi, Gaku& Matsumoto, Celso Soiti& Shinoda, Kei& Matsumoto, Harue& Mizota, Atsushi. 2014. Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression. BioMed Research International،Vol. 2014, no. 2014, pp.1-5.
https://search.emarefa.net/detail/BIM-482899
Modern Language Association (MLA)
Terauchi, Gaku…[et al.]. Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression. BioMed Research International No. 2014 (2014), pp.1-5.
https://search.emarefa.net/detail/BIM-482899
American Medical Association (AMA)
Terauchi, Gaku& Matsumoto, Celso Soiti& Shinoda, Kei& Matsumoto, Harue& Mizota, Atsushi. Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-5.
https://search.emarefa.net/detail/BIM-482899
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-482899