Abstract EN

The effect of the diameter of an intraocular lens (IOL) implanted in enucleated porcine eyes on the intraocular pressure induced by scleral depression was investigated.

Two IOLs of 6 mm and 7 mm optic diameter were implanted.

The intraocular pressure (IOP) was monitored during scleral depression by a transducer placed in the midvitreous through a sclerotomy at 6 o’clock.

The area under the curve (AUC) of the IOP changes from the beginning of the indentation to the point when the peripheral retinal surface was observed through the IOL optics was measured.

The AUC was significantly larger in eyes with a 6 mm IOL than in eyes with a 7 mm IOL (p<0.05).

The IOP elevation at the endpoint was higher in eyes with the 6 mm IOL than in eyes with the 7 mm IOL.

We conclude that the AUC may represent the degree of stress induced by scleral depression.

The higher AUC value with the X-60 may be because of the longer distance from the peripheral retina to the edge of the IOL optics.

American Psychological Association (APA)

Terauchi, Gaku& Matsumoto, Celso Soiti& Shinoda, Kei& Matsumoto, Harue& Mizota, Atsushi. 2014. Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression. BioMed Research International،Vol. 2014, no. 2014, pp.1-5.
https://search.emarefa.net/detail/BIM-482899

Modern Language Association (MLA)

Terauchi, Gaku…[et al.]. Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression. BioMed Research International No. 2014 (2014), pp.1-5.
https://search.emarefa.net/detail/BIM-482899

American Medical Association (AMA)

Terauchi, Gaku& Matsumoto, Celso Soiti& Shinoda, Kei& Matsumoto, Harue& Mizota, Atsushi. Effect of Intraocular Lens Diameter Implanted in Enucleated Porcine Eye on Intraocular Pressure Induced by Scleral Depression. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-5.
https://search.emarefa.net/detail/BIM-482899

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-482899