![](/images/graphics-bg.png)
Semiautomatic Segmentation of Ventilated Airspaces in Healthy and Asthmatic Subjects Using Hyperpolarized 3He MRI
المؤلفون المشاركون
Lutchen, K. R.
Parameswaran, H.
LaPrad, A. S.
Lui, J. K.
Albert, M. S.
Sun, Y.
المصدر
Computational and Mathematical Methods in Medicine
العدد
المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-9، 9ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2013-03-31
دولة النشر
مصر
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
A segmentation algorithm to isolate areas of ventilation from hyperpolarized helium-3 magnetic resonance imaging (HP 3He MRI) is described.
The algorithm was tested with HP 3He MRI data from four healthy and six asthmatic subjects.
Ventilated lung volume (VLV) measured using our semiautomated technique was compared to that obtained from manual outlining of ventilated lung regions and to standard spirometric measurements.
VLVs from both approaches were highly correlated (R=0.99; P<0.0001) with a mean difference of 3.8 mL and 95% agreement indices of −30.8 mL and 38.4 mL.
There was no significant difference between the VLVs obtained through the semiautomatic approach and the manual approach.
A Dice coefficient which quantified the intersection of the two datasets was calculated and ranged from 0.95 to 0.97 with a mean of 0.96 ± 0.01 (mean ± SD).
VLVs obtained through the semiautomatic algorithm were also highly correlated with measurements of forced expiratory volume in one second (FEV1) (R=0.82; P=0.0035) and forced vital capacity (FVC) (R=0.95; P<0.0001).
The technique may open new pathways toward advancing more quantitative characterization of ventilation for routine clinical assessment for asthma severity as well as a number of other respiratory diseases.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Lui, J. K.& LaPrad, A. S.& Parameswaran, H.& Sun, Y.& Albert, M. S.& Lutchen, K. R.. 2013. Semiautomatic Segmentation of Ventilated Airspaces in Healthy and Asthmatic Subjects Using Hyperpolarized 3He MRI. Computational and Mathematical Methods in Medicine،Vol. 2013, no. 2013, pp.1-9.
https://search.emarefa.net/detail/BIM-486061
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Lui, J. K.…[et al.]. Semiautomatic Segmentation of Ventilated Airspaces in Healthy and Asthmatic Subjects Using Hyperpolarized 3He MRI. Computational and Mathematical Methods in Medicine No. 2013 (2013), pp.1-9.
https://search.emarefa.net/detail/BIM-486061
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Lui, J. K.& LaPrad, A. S.& Parameswaran, H.& Sun, Y.& Albert, M. S.& Lutchen, K. R.. Semiautomatic Segmentation of Ventilated Airspaces in Healthy and Asthmatic Subjects Using Hyperpolarized 3He MRI. Computational and Mathematical Methods in Medicine. 2013. Vol. 2013, no. 2013, pp.1-9.
https://search.emarefa.net/detail/BIM-486061
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-486061
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)