Shear Stress, Energy Losses, and Costs : A Resolved Dilemma of Pulsatile Cardiac Assist Devices

المؤلفون المشاركون

Chachques, Juan Carlos
Wang, Qinmei
Carbognani, Daniel
Wu, Guifu
Yang, Daya
Dai, Gang
Liu, Jia
Nour, Sayed

المصدر

BioMed Research International

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-12، 12ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-01-08

دولة النشر

مصر

عدد الصفحات

12

التخصصات الرئيسية

الطب البشري

الملخص EN

Cardiac assist devices (CAD) cause endothelial dysfunction with considerable morbidity.

Employment of pulsatile CAD remains controversial due to inadequate perfusion curves and costs.

Alternatively, we are proposing a new concept of pulsatile CAD based on a fundamental revision of the entire circulatory system in correspondence with the physiopathology and law of physics.

It concerns a double lumen disposable tube device that could be adapted to conventional cardiopulmonary bypass (CPB) and/or CAD, for inducing a homogenous, downstream pulsatile perfusion mode with lower energy losses.

In this study, the device’s prototypes were tested in a simulated conventional pediatric CPB circuit for energy losses and as a left ventricular assist device (LVAD) in ischemic piglets model for endothelial shear stress (ESS) evaluations.

In conclusion and according to the study results the pulsatile tube was successfully capable of transforming a conventional CPB and/or CAD steady flow into a pulsatile perfusion mode, with nearly physiologic pulse pressure and lower energy losses.

This represents a cost-effective promising method with low mortality and morbidity, especially in fragile cardiac patients.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Nour, Sayed& Liu, Jia& Dai, Gang& Carbognani, Daniel& Yang, Daya& Wu, Guifu…[et al.]. 2014. Shear Stress, Energy Losses, and Costs : A Resolved Dilemma of Pulsatile Cardiac Assist Devices. BioMed Research International،Vol. 2014, no. 2014, pp.1-12.
https://search.emarefa.net/detail/BIM-488350

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Nour, Sayed…[et al.]. Shear Stress, Energy Losses, and Costs : A Resolved Dilemma of Pulsatile Cardiac Assist Devices. BioMed Research International No. 2014 (2014), pp.1-12.
https://search.emarefa.net/detail/BIM-488350

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Nour, Sayed& Liu, Jia& Dai, Gang& Carbognani, Daniel& Yang, Daya& Wu, Guifu…[et al.]. Shear Stress, Energy Losses, and Costs : A Resolved Dilemma of Pulsatile Cardiac Assist Devices. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-12.
https://search.emarefa.net/detail/BIM-488350

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-488350