Prevention of Peritendinous Adhesions Using an Electrospun DegraPol Polymer Tube : A Histological, Ultrasonographic, and Biomechanical Study in Rabbits
المؤلفون المشاركون
Calcagni, Maurizio
Fessel, Gion
Müller, Angela
Giovanoli, Pietro
Meier Bürgisser, Gabriella
Buschmann, Johanna
Bonavoglia, Eliana
Snedeker, Jess G.
المصدر
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-11، 11ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-07-02
دولة النشر
مصر
عدد الصفحات
11
التخصصات الرئيسية
الملخص EN
Purpose.
One of the great challenges in surgical tendon rupture repair is to minimize peritendinous adhesions.
In order to reduce adhesion formation, a physical barrier was applied to a sutured rabbit Achilles tendon, with two different immobilization protocols used postoperatively.
Methods.
Thirty New Zealand white rabbits received a laceration on the Achilles tendon, sutured with a 4-strand Becker suture, and half of the rabbits got a DegraPol tube at the repair site.
While fifteen rabbits had their treated hind leg in a 180° stretched position during 6 weeks (adhesion provoking immobilization), the other fifteen rabbits were recasted with a 150° position after 3 weeks (adhesion inhibiting immobilization).
Adhesion extent was analysed macroscopically, via ultrasound and histology.
Inflammation was determined histologically.
Biomechanical properties were analysed.
Results.
Application of a DegraPol tube reduced adhesion formation by approximately 20%—independently of the immobilization protocol.
Biomechanical properties of extracted specimen were not affected by the tube application.
There was no serious inflammatory reaction towards the implant material.
Conclusions.
Implantation of a DegraPol tube tightly set around a sutured tendon acts as a beneficial physical barrier and prevents adhesion formation significantly—without affecting the tendon healing process.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Meier Bürgisser, Gabriella& Calcagni, Maurizio& Müller, Angela& Bonavoglia, Eliana& Fessel, Gion& Snedeker, Jess G.…[et al.]. 2014. Prevention of Peritendinous Adhesions Using an Electrospun DegraPol Polymer Tube : A Histological, Ultrasonographic, and Biomechanical Study in Rabbits. BioMed Research International،Vol. 2014, no. 2014, pp.1-11.
https://search.emarefa.net/detail/BIM-488705
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Meier Bürgisser, Gabriella…[et al.]. Prevention of Peritendinous Adhesions Using an Electrospun DegraPol Polymer Tube : A Histological, Ultrasonographic, and Biomechanical Study in Rabbits. BioMed Research International No. 2014 (2014), pp.1-11.
https://search.emarefa.net/detail/BIM-488705
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Meier Bürgisser, Gabriella& Calcagni, Maurizio& Müller, Angela& Bonavoglia, Eliana& Fessel, Gion& Snedeker, Jess G.…[et al.]. Prevention of Peritendinous Adhesions Using an Electrospun DegraPol Polymer Tube : A Histological, Ultrasonographic, and Biomechanical Study in Rabbits. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-11.
https://search.emarefa.net/detail/BIM-488705
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-488705
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر