Evaluation of Micromovements and Stresses around Single Wide-Diameter and Double Implants for Replacing Mandibular Molar : A Three-Dimensional FEA

المؤلفون المشاركون

Desai, Shrikar R.
Karthikeyan, I.
Singh, Rika

المصدر

ISRN Dentistry

العدد

المجلد 2012، العدد 2012 (31 ديسمبر/كانون الأول 2012)، ص ص. 1-10، 10ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2012-03-07

دولة النشر

مصر

عدد الصفحات

10

التخصصات الرئيسية

طب الأسنان

الملخص EN

Purpose.

The purpose of this finite element study was to compare stresses, strains, and displacements of double versus single implant, in immediate loading for replacing mandibular molar.

Materials and Methods.

Two 3D FEM models were made to simulate implant designs.

The first model used 6 mm wide-diameter implant to support a single molar crown.

The second model used 3.75-3.75 double implant design.

Each model was analyzed with a single force magnitude of 70 N in oblique axis in three locations.

Results.

This FEM study suggested that micromotion can be well controlled by both double implants and 6 mm single wide-diameter implant.

The Von Mises stress for double implant had 31%–43% stress reduction compared to the 6 mm implant.

Conclusion.

Within the limitations of the paper, when the mesiodistal space for artificial tooth is more than 12.5 mm, under immediate loading, the double implant support should be considered.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Desai, Shrikar R.& Karthikeyan, I.& Singh, Rika. 2012. Evaluation of Micromovements and Stresses around Single Wide-Diameter and Double Implants for Replacing Mandibular Molar : A Three-Dimensional FEA. ISRN Dentistry،Vol. 2012, no. 2012, pp.1-10.
https://search.emarefa.net/detail/BIM-489984

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Desai, Shrikar R.…[et al.]. Evaluation of Micromovements and Stresses around Single Wide-Diameter and Double Implants for Replacing Mandibular Molar : A Three-Dimensional FEA. ISRN Dentistry No. 2012 (2012), pp.1-10.
https://search.emarefa.net/detail/BIM-489984

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Desai, Shrikar R.& Karthikeyan, I.& Singh, Rika. Evaluation of Micromovements and Stresses around Single Wide-Diameter and Double Implants for Replacing Mandibular Molar : A Three-Dimensional FEA. ISRN Dentistry. 2012. Vol. 2012, no. 2012, pp.1-10.
https://search.emarefa.net/detail/BIM-489984

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-489984