Evaluation of Micromovements and Stresses around Single Wide-Diameter and Double Implants for Replacing Mandibular Molar : A Three-Dimensional FEA
Joint Authors
Desai, Shrikar R.
Karthikeyan, I.
Singh, Rika
Source
Issue
Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-10, 10 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2012-03-07
Country of Publication
Egypt
No. of Pages
10
Main Subjects
Abstract EN
Purpose.
The purpose of this finite element study was to compare stresses, strains, and displacements of double versus single implant, in immediate loading for replacing mandibular molar.
Materials and Methods.
Two 3D FEM models were made to simulate implant designs.
The first model used 6 mm wide-diameter implant to support a single molar crown.
The second model used 3.75-3.75 double implant design.
Each model was analyzed with a single force magnitude of 70 N in oblique axis in three locations.
Results.
This FEM study suggested that micromotion can be well controlled by both double implants and 6 mm single wide-diameter implant.
The Von Mises stress for double implant had 31%–43% stress reduction compared to the 6 mm implant.
Conclusion.
Within the limitations of the paper, when the mesiodistal space for artificial tooth is more than 12.5 mm, under immediate loading, the double implant support should be considered.
American Psychological Association (APA)
Desai, Shrikar R.& Karthikeyan, I.& Singh, Rika. 2012. Evaluation of Micromovements and Stresses around Single Wide-Diameter and Double Implants for Replacing Mandibular Molar : A Three-Dimensional FEA. ISRN Dentistry،Vol. 2012, no. 2012, pp.1-10.
https://search.emarefa.net/detail/BIM-489984
Modern Language Association (MLA)
Desai, Shrikar R.…[et al.]. Evaluation of Micromovements and Stresses around Single Wide-Diameter and Double Implants for Replacing Mandibular Molar : A Three-Dimensional FEA. ISRN Dentistry No. 2012 (2012), pp.1-10.
https://search.emarefa.net/detail/BIM-489984
American Medical Association (AMA)
Desai, Shrikar R.& Karthikeyan, I.& Singh, Rika. Evaluation of Micromovements and Stresses around Single Wide-Diameter and Double Implants for Replacing Mandibular Molar : A Three-Dimensional FEA. ISRN Dentistry. 2012. Vol. 2012, no. 2012, pp.1-10.
https://search.emarefa.net/detail/BIM-489984
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-489984