![](/images/graphics-bg.png)
MRI-Based Multiscale Model for Electromagnetic Analysis in the Human Head with Implanted DBS
المؤلفون المشاركون
Iacono, Maria Ida
Angelone, Leonardo M.
Makris, Nikos
Bonmassar, Giorgio
Mainardi, Luca
المصدر
Computational and Mathematical Methods in Medicine
العدد
المجلد 2013، العدد 2013 (31 ديسمبر/كانون الأول 2013)، ص ص. 1-12، 12ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2013-07-15
دولة النشر
مصر
عدد الصفحات
12
التخصصات الرئيسية
الملخص EN
Deep brain stimulation (DBS) is an established procedure for the treatment of movement and affective disorders.
Patients with DBS may benefit from magnetic resonance imaging (MRI) to evaluate injuries or comorbidities.
However, the MRI radio-frequency (RF) energy may cause excessive tissue heating particularly near the electrode.
This paper studies how the accuracy of numerical modeling of the RF field inside a DBS patient varies with spatial resolution and corresponding anatomical detail of the volume surrounding the electrodes.
A multiscale model (MS) was created by an atlas-based segmentation using a 1 mm3 head model (mRes) refined in the basal ganglia by a 200 μm2 ex-vivo dataset.
Four DBS electrodes targeting the left globus pallidus internus were modeled.
Electromagnetic simulations at 128 MHz showed that the peak of the electric field of the MS doubled (18.7 kV/m versus 9.33 kV/m) and shifted 6.4 mm compared to the mRes model.
Additionally, the MS had a sixfold increase over the mRes model in peak-specific absorption rate (SAR of 43.9 kW/kg versus 7 kW/kg).
The results suggest that submillimetric resolution and improved anatomical detail in the model may increase the accuracy of computed electric field and local SAR around the tip of the implant.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Iacono, Maria Ida& Makris, Nikos& Mainardi, Luca& Angelone, Leonardo M.& Bonmassar, Giorgio. 2013. MRI-Based Multiscale Model for Electromagnetic Analysis in the Human Head with Implanted DBS. Computational and Mathematical Methods in Medicine،Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-491164
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Iacono, Maria Ida…[et al.]. MRI-Based Multiscale Model for Electromagnetic Analysis in the Human Head with Implanted DBS. Computational and Mathematical Methods in Medicine No. 2013 (2013), pp.1-12.
https://search.emarefa.net/detail/BIM-491164
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Iacono, Maria Ida& Makris, Nikos& Mainardi, Luca& Angelone, Leonardo M.& Bonmassar, Giorgio. MRI-Based Multiscale Model for Electromagnetic Analysis in the Human Head with Implanted DBS. Computational and Mathematical Methods in Medicine. 2013. Vol. 2013, no. 2013, pp.1-12.
https://search.emarefa.net/detail/BIM-491164
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-491164
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)