A wide range of studies show the capacity of multivariate statistical methods for fMRI to improve mapping of brain activations in a noisy environment.

An advanced method uses local canonical correlation analysis (CCA) to encompass a group of neighboring voxels instead of looking at the single voxel time course.

The value of a suitable test statistic is used as a measure of activation.

It is customary to assign the value to the center voxel; however, this is a choice of convenience and without constraints introduces artifacts, especially in regions of strong localized activation.

To compensate for these deficiencies, different spatial constraints in CCA have been introduced to enforce dominance of the center voxel.

However, even if the dominance condition for the center voxel is satisfied, constrained CCA can still lead to a smoothing artifact, often called the “bleeding artifact of CCA”, in fMRI activation patterns.

In this paper a new method is introduced to measure and correct for the smoothing artifact for constrained CCA methods.

It is shown that constrained CCA methods corrected for the smoothing artifact lead to more plausible activation patterns in fMRI as shown using data from a motor task and a memory task.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Cordes, Dietmar& Jin, Mingwu& Curran, Tim& Nandy, Rajesh. 2012. The Smoothing Artifact of Spatially Constrained Canonical Correlation Analysis in Functional MRI. International Journal of Biomedical Imaging،Vol. 2012, no. 2012, pp.1-11.
https://search.emarefa.net/detail/BIM-494751

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Cordes, Dietmar…[et al.]. The Smoothing Artifact of Spatially Constrained Canonical Correlation Analysis in Functional MRI. International Journal of Biomedical Imaging No. 2012 (2012), pp.1-11.
https://search.emarefa.net/detail/BIM-494751

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Cordes, Dietmar& Jin, Mingwu& Curran, Tim& Nandy, Rajesh. The Smoothing Artifact of Spatially Constrained Canonical Correlation Analysis in Functional MRI. International Journal of Biomedical Imaging. 2012. Vol. 2012, no. 2012, pp.1-11.
https://search.emarefa.net/detail/BIM-494751

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-494751