Evaluation of Assays for Measurement of Serum (Anti)oxidants in Hemodialysis Patients
المؤلفون المشاركون
Ruskovska, Tatjana
Antarorov, Risto
Jansen, Eugene H. J. M.
المصدر
العدد
المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2014-05-19
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Background.
Various biomarkers and assays have been used for assessment of (anti)oxidant status in hemodialysis patients, including those intended for measurement of serum total (anti)oxidants, most often as a part of panel biomarkers.
Methods.
Serum (anti)oxidant status was measured in 32 chronically hemodialyzed patients and in 47 healthy persons, using two oxidations and three antioxidant assays.
Results.
The patients before the hemodialysis session have had higher values of total oxidants in comparison to the healthy persons, with a further increase during the hemodialysis.
These findings were confirmed with both oxidation assays, but they differ in the percentage of increase and the statistical significance.
All three antioxidant assays showed significantly higher values of the total serum antioxidants in the patients before the hemodialysis session in comparison to the healthy persons, and their significant decrease during the hemodialysis.
However, the assays differ in the percentage of decrease, its statistical significance, and the correlations with uric acid.
Conclusion.
The variability of results of total (anti)oxidants which are obtained using different assays should be taken into account when interpreting data from clinical studies of oxidative stress, especially in complex pathologies such as chronic hemodialysis.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Ruskovska, Tatjana& Jansen, Eugene H. J. M.& Antarorov, Risto. 2014. Evaluation of Assays for Measurement of Serum (Anti)oxidants in Hemodialysis Patients. BioMed Research International،Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-502681
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Ruskovska, Tatjana…[et al.]. Evaluation of Assays for Measurement of Serum (Anti)oxidants in Hemodialysis Patients. BioMed Research International No. 2014 (2014), pp.1-8.
https://search.emarefa.net/detail/BIM-502681
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Ruskovska, Tatjana& Jansen, Eugene H. J. M.& Antarorov, Risto. Evaluation of Assays for Measurement of Serum (Anti)oxidants in Hemodialysis Patients. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-8.
https://search.emarefa.net/detail/BIM-502681
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-502681
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر