Experimental Characterization of a Passive Emergency Heat Removal System for a GenIII+ Reactor

المؤلفون المشاركون

Papini, Davide
Ricotti, Marco E.
Santini, Lorenzo

المصدر

Science and Technology of Nuclear Installations

العدد

المجلد 2010، العدد 2010 (31 ديسمبر/كانون الأول 2010)، ص ص. 1-12، 12ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2009-12-30

دولة النشر

مصر

عدد الصفحات

12

التخصصات الرئيسية

العلوم الهندسية و تكنولوجيا المعلومات

الملخص EN

Among the several types of passive safety systems adopted in new generation reactor designs, the experimental investigation of a closed loop, two-phase flow, natural circulation system is depicted.

Emergency Heat Removal Systems (EHRSs) based on this solution are envisaged as safety-engineered features for advanced nuclear reactors, as in the IRIS reactor.

An experimental facility simulating one EHRS-like loop has been built and operated at SIET labs in Piacenza (Italy).

The facility is a natural circulation, sliding pressure, and electrically heated loop, with a helical coil steam generator as a heat source and a horizontal tube pool condenser as a heat sink.

A steady-state analysis is provided to characterize the system behaviour and its key parameters.

Because of the loop limited volume, oscillations of the main parameters (temperatures, flowrate, pressure) may be expected.

The oscillating phenomena detected during the experimental campaign are discussed; a reasonable explanation is at last proposed.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Santini, Lorenzo& Papini, Davide& Ricotti, Marco E.. 2009. Experimental Characterization of a Passive Emergency Heat Removal System for a GenIII+ Reactor. Science and Technology of Nuclear Installations،Vol. 2010, no. 2010, pp.1-12.
https://search.emarefa.net/detail/BIM-504502

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Santini, Lorenzo…[et al.]. Experimental Characterization of a Passive Emergency Heat Removal System for a GenIII+ Reactor. Science and Technology of Nuclear Installations No. 2010 (2010), pp.1-12.
https://search.emarefa.net/detail/BIM-504502

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Santini, Lorenzo& Papini, Davide& Ricotti, Marco E.. Experimental Characterization of a Passive Emergency Heat Removal System for a GenIII+ Reactor. Science and Technology of Nuclear Installations. 2009. Vol. 2010, no. 2010, pp.1-12.
https://search.emarefa.net/detail/BIM-504502

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-504502