Experimental Characterization of a Passive Emergency Heat Removal System for a GenIII+ Reactor

Joint Authors

Papini, Davide
Ricotti, Marco E.
Santini, Lorenzo

Source

Science and Technology of Nuclear Installations

Issue

Vol. 2010, Issue 2010 (31 Dec. 2010), pp.1-12, 12 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2009-12-30

Country of Publication

Egypt

No. of Pages

12

Main Subjects

Engineering Sciences and Information Technology

Abstract EN

Among the several types of passive safety systems adopted in new generation reactor designs, the experimental investigation of a closed loop, two-phase flow, natural circulation system is depicted.

Emergency Heat Removal Systems (EHRSs) based on this solution are envisaged as safety-engineered features for advanced nuclear reactors, as in the IRIS reactor.

An experimental facility simulating one EHRS-like loop has been built and operated at SIET labs in Piacenza (Italy).

The facility is a natural circulation, sliding pressure, and electrically heated loop, with a helical coil steam generator as a heat source and a horizontal tube pool condenser as a heat sink.

A steady-state analysis is provided to characterize the system behaviour and its key parameters.

Because of the loop limited volume, oscillations of the main parameters (temperatures, flowrate, pressure) may be expected.

The oscillating phenomena detected during the experimental campaign are discussed; a reasonable explanation is at last proposed.

American Psychological Association (APA)

Santini, Lorenzo& Papini, Davide& Ricotti, Marco E.. 2009. Experimental Characterization of a Passive Emergency Heat Removal System for a GenIII+ Reactor. Science and Technology of Nuclear Installations،Vol. 2010, no. 2010, pp.1-12.
https://search.emarefa.net/detail/BIM-504502

Modern Language Association (MLA)

Santini, Lorenzo…[et al.]. Experimental Characterization of a Passive Emergency Heat Removal System for a GenIII+ Reactor. Science and Technology of Nuclear Installations No. 2010 (2010), pp.1-12.
https://search.emarefa.net/detail/BIM-504502

American Medical Association (AMA)

Santini, Lorenzo& Papini, Davide& Ricotti, Marco E.. Experimental Characterization of a Passive Emergency Heat Removal System for a GenIII+ Reactor. Science and Technology of Nuclear Installations. 2009. Vol. 2010, no. 2010, pp.1-12.
https://search.emarefa.net/detail/BIM-504502

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-504502