Enhanced Blood Compatibility of Metallocene Polyethylene Subjected to Hydrochloric Acid Treatment for Cardiovascular Implants

المؤلفون المشاركون

Murugesan, Selvakumar
Jaganathan, Saravana Kumar
Sudheer, Theertha
Mohandas, Hemanth
Kasi, Palaniappan
Supriyanto, Eko
Sivakumar, Gunalan
Avineri Veetil, Sruthi

المصدر

BioMed Research International

العدد

المجلد 2014، العدد 2014 (31 ديسمبر/كانون الأول 2014)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2014-05-14

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الطب البشري

الملخص EN

Blood compatibility of metallocene polyethylene (mPE) was investigated after modifying the surface using hydrochloric acid.

Contact angle of the mPE exposed to HCl poses a decrease in its value which indicates increasing wettability and better blood compatibility.

Surface of mPE analyzed by using FTIR revealed no significant changes in its functional groups after treatment.

Furthermore, scanning electron microscope images supported the increasing wettability through the modifications like pit formations and etching on the acid rendered surface.

To evaluate the effect of acid treatment on the coagulation cascade, prothrombin time (PT) and activated partial thromboplastin time (APTT) were measured.

Both PT and APTT were delayed significantly (P<0.05) after 60 min exposure implying improved blood compatibility of the surfaces.

Hemolysis assay of the treated surface showed a remarkable decrease in the percentage of lysis of red blood cells when compared with untreated surface.

Moreover, platelet adhesion assay demonstrated that HCl exposed surfaces deter the attachment of platelets and thereby reduce the chances of activation of blood coagulation cascade.

These results confirmed the enhanced blood compatibility of mPE after HCl exposure which can be utilized for cardiovascular implants like artificial vascular prostheses, implants, and various blood contacting devices.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Jaganathan, Saravana Kumar& Mohandas, Hemanth& Sivakumar, Gunalan& Kasi, Palaniappan& Sudheer, Theertha& Avineri Veetil, Sruthi…[et al.]. 2014. Enhanced Blood Compatibility of Metallocene Polyethylene Subjected to Hydrochloric Acid Treatment for Cardiovascular Implants. BioMed Research International،Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-511837

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Jaganathan, Saravana Kumar…[et al.]. Enhanced Blood Compatibility of Metallocene Polyethylene Subjected to Hydrochloric Acid Treatment for Cardiovascular Implants. BioMed Research International No. 2014 (2014), pp.1-7.
https://search.emarefa.net/detail/BIM-511837

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Jaganathan, Saravana Kumar& Mohandas, Hemanth& Sivakumar, Gunalan& Kasi, Palaniappan& Sudheer, Theertha& Avineri Veetil, Sruthi…[et al.]. Enhanced Blood Compatibility of Metallocene Polyethylene Subjected to Hydrochloric Acid Treatment for Cardiovascular Implants. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-7.
https://search.emarefa.net/detail/BIM-511837

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-511837