Improving coefficient of thermal performance and electricity saving in the water chiller system

المؤلفون المشاركون

Hamzah, Sarah Q.
Hannun, Rafid Ma'allak

المصدر

Thi-Qar University Journal for Engineering Sciences

العدد

المجلد 10، العدد 2 (30 سبتمبر/أيلول 2019)، ص ص. 17-22، 6ص.

الناشر

جامعة ذي قار كلية الهندسة

تاريخ النشر

2019-09-30

دولة النشر

العراق

عدد الصفحات

6

التخصصات الرئيسية

الهندسة الميكانيكية

الملخص EN

A water chiller air-conditioning system has been completed.

Energy savings was estimated using different variables: calculation power consumption, electricity consumption, the cooling load of the testing room.

The system tested during the environment of Al- Muthanna province (Al-Rummaitha city), Iraq.

The measurements were taken during the summer months (May - June – July and August).

The results indicated a difference in energy saving during the daily operating hours, the highest reduction rate was obtained of cooling loads, which were based on the change in evaporator temperatures and also the highest percentage was achieved during August by 23 % and the lowest percentage during May by 5 %.

Thus, the study concluded that the percentage of electricity consumption during the months of May and August was 56% and 41 %, respectively.

This paper concludes the power electricity was 14.7 amperes in conventional air conditioners whereas the chiller air- conditioning was up to 1.07 amperes.

Also, the electricity saving was effected with lower storage tank water.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Hamzah, Sarah Q.& Hannun, Rafid Ma'allak. 2019. Improving coefficient of thermal performance and electricity saving in the water chiller system. Thi-Qar University Journal for Engineering Sciences،Vol. 10, no. 2, pp.17-22.
https://search.emarefa.net/detail/BIM-952990

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Hamzah, Sarah Q.& Hannun, Rafid Ma'allak. Improving coefficient of thermal performance and electricity saving in the water chiller system. Thi-Qar University Journal for Engineering Sciences Vol. 10, no. 2 (Sep. 2019), pp.17-22.
https://search.emarefa.net/detail/BIM-952990

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Hamzah, Sarah Q.& Hannun, Rafid Ma'allak. Improving coefficient of thermal performance and electricity saving in the water chiller system. Thi-Qar University Journal for Engineering Sciences. 2019. Vol. 10, no. 2, pp.17-22.
https://search.emarefa.net/detail/BIM-952990

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 22

رقم السجل

BIM-952990