Improving coefficient of thermal performance and electricity saving in the water chiller system
Joint Authors
Hamzah, Sarah Q.
Hannun, Rafid Ma'allak
Source
Thi-Qar University Journal for Engineering Sciences
Issue
Vol. 10, Issue 2 (30 Sep. 2019), pp.17-22, 6 p.
Publisher
University of Thi-Qar College of Engineering
Publication Date
2019-09-30
Country of Publication
Iraq
No. of Pages
6
Main Subjects
Abstract EN
A water chiller air-conditioning system has been completed.
Energy savings was estimated using different variables: calculation power consumption, electricity consumption, the cooling load of the testing room.
The system tested during the environment of Al- Muthanna province (Al-Rummaitha city), Iraq.
The measurements were taken during the summer months (May - June – July and August).
The results indicated a difference in energy saving during the daily operating hours, the highest reduction rate was obtained of cooling loads, which were based on the change in evaporator temperatures and also the highest percentage was achieved during August by 23 % and the lowest percentage during May by 5 %.
Thus, the study concluded that the percentage of electricity consumption during the months of May and August was 56% and 41 %, respectively.
This paper concludes the power electricity was 14.7 amperes in conventional air conditioners whereas the chiller air- conditioning was up to 1.07 amperes.
Also, the electricity saving was effected with lower storage tank water.
American Psychological Association (APA)
Hamzah, Sarah Q.& Hannun, Rafid Ma'allak. 2019. Improving coefficient of thermal performance and electricity saving in the water chiller system. Thi-Qar University Journal for Engineering Sciences،Vol. 10, no. 2, pp.17-22.
https://search.emarefa.net/detail/BIM-952990
Modern Language Association (MLA)
Hamzah, Sarah Q.& Hannun, Rafid Ma'allak. Improving coefficient of thermal performance and electricity saving in the water chiller system. Thi-Qar University Journal for Engineering Sciences Vol. 10, no. 2 (Sep. 2019), pp.17-22.
https://search.emarefa.net/detail/BIM-952990
American Medical Association (AMA)
Hamzah, Sarah Q.& Hannun, Rafid Ma'allak. Improving coefficient of thermal performance and electricity saving in the water chiller system. Thi-Qar University Journal for Engineering Sciences. 2019. Vol. 10, no. 2, pp.17-22.
https://search.emarefa.net/detail/BIM-952990
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references : p. 22
Record ID
BIM-952990