Development of a Multicommutated Flow System with Chemiluminometric Detection for Quantification of Gentamicin in Pharmaceuticals

المؤلفون المشاركون

Montenegro, M. C. B. S. M.
Santos, Lúcia H. M. L. M.
Reis, Boaventura F.
Araújo, A. N.

المصدر

Journal of Analytical Methods in Chemistry

العدد

المجلد 2010، العدد 2010 (31 ديسمبر/كانون الأول 2010)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2010-09-13

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الكيمياء

الملخص EN

A new flow procedure based on multicommutation with chemiluminometric detection was developed to quantify gentamicin sulphate in pharmaceutical formulations.

This approach is based on gentamicin's ability to inhibit the chemiluminometric reaction between luminol and hypochlorite in alkaline medium, causing a decrease in the analytical signal.

The inhibition of the analytical signal is proportional to the concentration of gentamicin sulphate, within a linear range of 1 to 4 μg mL-1 with a coefficient variation <3%.

A sample throughput of 55 samples h-1 was obtained.

The developed method is sensitive, simple, with low reagent consumption, reproducible, and inexpensive, and when applied to the analysis of pharmaceutical formulations (eye drops and injections) it gave results with RSD between 1.10 and 4.40%.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Santos, Lúcia H. M. L. M.& Araújo, A. N.& Reis, Boaventura F.& Montenegro, M. C. B. S. M.. 2010. Development of a Multicommutated Flow System with Chemiluminometric Detection for Quantification of Gentamicin in Pharmaceuticals. Journal of Analytical Methods in Chemistry،Vol. 2010, no. 2010, pp.1-7.
https://search.emarefa.net/detail/BIM-989243

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Santos, Lúcia H. M. L. M.…[et al.]. Development of a Multicommutated Flow System with Chemiluminometric Detection for Quantification of Gentamicin in Pharmaceuticals. Journal of Analytical Methods in Chemistry No. 2010 (2010), pp.1-7.
https://search.emarefa.net/detail/BIM-989243

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Santos, Lúcia H. M. L. M.& Araújo, A. N.& Reis, Boaventura F.& Montenegro, M. C. B. S. M.. Development of a Multicommutated Flow System with Chemiluminometric Detection for Quantification of Gentamicin in Pharmaceuticals. Journal of Analytical Methods in Chemistry. 2010. Vol. 2010, no. 2010, pp.1-7.
https://search.emarefa.net/detail/BIM-989243

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-989243