Validation and Development of a New Automatic Algorithm for Time-Resolved Segmentation of the Left Ventricle in Magnetic Resonance Imaging

Joint Authors

Tufvesson, Jane
Hedström, Erik
Steding-Ehrenborg, Katarina
Carlsson, Marcus
Arheden, Håkan
Heiberg, Einar

Source

BioMed Research International

Issue

Vol. 2015, Issue 2015 (31 Dec. 2015), pp.1-12, 12 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2015-06-21

Country of Publication

Egypt

No. of Pages

12

Main Subjects

Medicine

Abstract EN

Introduction.

Manual delineation of the left ventricle is clinical standard for quantification of cardiovascular magnetic resonance images despite being time consuming and observer dependent.

Previous automatic methods generally do not account for one major contributor to stroke volume, the long-axis motion.

Therefore, the aim of this study was to develop and validate an automatic algorithm for time-resolved segmentation covering the whole left ventricle, including basal slices affected by long-axis motion.

Methods.

Ninety subjects imaged with a cine balanced steady state free precession sequence were included in the study (training set n = 40 , test set n = 50 ).

Manual delineation was reference standard and second observer analysis was performed in a subset ( n = 25 ).

The automatic algorithm uses deformable model with expectation-maximization, followed by automatic removal of papillary muscles and detection of the outflow tract.

Results.

The mean differences between automatic segmentation and manual delineation were EDV −11 mL, ESV 1 mL, EF −3%, and LVM 4 g in the test set.

Conclusions.

The automatic LV segmentation algorithm reached accuracy comparable to interobserver for manual delineation, thereby bringing automatic segmentation one step closer to clinical routine.

The algorithm and all images with manual delineations are available for benchmarking.

American Psychological Association (APA)

Tufvesson, Jane& Hedström, Erik& Steding-Ehrenborg, Katarina& Carlsson, Marcus& Arheden, Håkan& Heiberg, Einar. 2015. Validation and Development of a New Automatic Algorithm for Time-Resolved Segmentation of the Left Ventricle in Magnetic Resonance Imaging. BioMed Research International،Vol. 2015, no. 2015, pp.1-12.
https://search.emarefa.net/detail/BIM-1057433

Modern Language Association (MLA)

Tufvesson, Jane…[et al.]. Validation and Development of a New Automatic Algorithm for Time-Resolved Segmentation of the Left Ventricle in Magnetic Resonance Imaging. BioMed Research International No. 2015 (2015), pp.1-12.
https://search.emarefa.net/detail/BIM-1057433

American Medical Association (AMA)

Tufvesson, Jane& Hedström, Erik& Steding-Ehrenborg, Katarina& Carlsson, Marcus& Arheden, Håkan& Heiberg, Einar. Validation and Development of a New Automatic Algorithm for Time-Resolved Segmentation of the Left Ventricle in Magnetic Resonance Imaging. BioMed Research International. 2015. Vol. 2015, no. 2015, pp.1-12.
https://search.emarefa.net/detail/BIM-1057433

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1057433