A Simple and Improved HPLC-PDA Method for Simultaneous Estimation of Fexofenadine and Pseudoephedrine in Extended Release Tablets by Response Surface Methodology

Joint Authors

Kayesh, Ruhul
Sarker, A. S. M. Moniruzzaman
Sultan, Md. Zakir
Jahan, Md. Sarowar

Source

Journal of Chemistry

Issue

Vol. 2017, Issue 2017 (31 Dec. 2017), pp.1-10, 10 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2017-01-04

Country of Publication

Egypt

No. of Pages

10

Main Subjects

Chemistry

Abstract EN

A simple RP-HPLC method has been developed for simultaneous estimation of fexofenadine and pseudoephedrine in their extended release tablet.

The method was developed based on statistical design of experiments (DoE) and Response Surface Methodology.

Separation was achieved on double end-capped C18 column (250 mm × 4 mm, 5 μm).

In this experiment, two components of mobile phase, namely, acetonitrile (% v/v) and methanol (% v/v), were the factors whereas retention and resolution of the chromatographic peaks were the responses.

The effects of different composition of factors on the corresponding responses were investigated.

The optimum chromatographic condition for the current case was found as an isocratic mobile phase consisting of 20 mM phosphate buffer (pH 6.8) and acetonitrile and methanol in a ratio of 50 : 36 : 14 (% v/v) at a flow rate of 1 mL/min for 7 minutes.

The retention of pseudoephedrine and fexofenadine was found to be 2.6 min and 4.7 min, respectively.

The method was validated according to the ICH and FDA guidelines and various validation parameters were determined.

Also, forced degradation studies in acid, base, oxidation, and reduction media and in thermal condition were performed to establish specificity and stability-indicating property of this method.

Practical applicability of this method was checked in extended release tablets available in Bangladeshi market.

American Psychological Association (APA)

Kayesh, Ruhul& Sarker, A. S. M. Moniruzzaman& Sultan, Md. Zakir& Jahan, Md. Sarowar. 2017. A Simple and Improved HPLC-PDA Method for Simultaneous Estimation of Fexofenadine and Pseudoephedrine in Extended Release Tablets by Response Surface Methodology. Journal of Chemistry،Vol. 2017, no. 2017, pp.1-10.
https://search.emarefa.net/detail/BIM-1172587

Modern Language Association (MLA)

Kayesh, Ruhul…[et al.]. A Simple and Improved HPLC-PDA Method for Simultaneous Estimation of Fexofenadine and Pseudoephedrine in Extended Release Tablets by Response Surface Methodology. Journal of Chemistry No. 2017 (2017), pp.1-10.
https://search.emarefa.net/detail/BIM-1172587

American Medical Association (AMA)

Kayesh, Ruhul& Sarker, A. S. M. Moniruzzaman& Sultan, Md. Zakir& Jahan, Md. Sarowar. A Simple and Improved HPLC-PDA Method for Simultaneous Estimation of Fexofenadine and Pseudoephedrine in Extended Release Tablets by Response Surface Methodology. Journal of Chemistry. 2017. Vol. 2017, no. 2017, pp.1-10.
https://search.emarefa.net/detail/BIM-1172587

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1172587