Evaluation of Tensile Force in a Porcine Trachea Using a Reflective Optical Method

Joint Authors

Lomelí-Mejía, Pedro A.
Araujo-Monsalvo, Víctor M.
López-Sánchez, Alberto
Huerta-Azuara, Andrés
Aguirre-Palomé, Crystal
Domínguez-Hernández, Víctor M.
Cruz-Orea, Alfredo

Source

Journal of Spectroscopy

Issue

Vol. 2020, Issue 2020 (31 Dec. 2020), pp.1-6, 6 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2020-03-21

Country of Publication

Egypt

No. of Pages

6

Main Subjects

Physics

Abstract EN

The trachea serves a variety of functions during breathing and swallowing.

In cases requiring a partial resection, the treatment may involve anastomosis of the healthy ends of the trachea.

The tension in the anastomosis should not exceed 1,000 g.

Traditional methods for estimating tension in the trachea are very invasive.

The aim of this work is to develop a noninvasive optical system devoted to estimate the tension of the trachea in vivo.

An optical system was designed using a light source and a photosensor.

To determine the most suitable wavelength for the light source, a photoacoustic spectroscopy study was performed.

To test the system, a cadaveric pig trachea was mounted on a universal testing machine, and it was subjected to three tensile tests of up to 30 mm elongation.

The optical response was measured at 0, 10, 20, and 30 mm elongation.

An exponential response was observed so that the optical voltage-response curves were adjusted, and three exponential equations were derived to correlate the voltage with the optical response.

We can conclude that the proposed optical system is able to noninvasively estimate the tension of a cadaveric porcine trachea.

American Psychological Association (APA)

Lomelí-Mejía, Pedro A.& Cruz-Orea, Alfredo& Araujo-Monsalvo, Víctor M.& López-Sánchez, Alberto& Huerta-Azuara, Andrés& Aguirre-Palomé, Crystal…[et al.]. 2020. Evaluation of Tensile Force in a Porcine Trachea Using a Reflective Optical Method. Journal of Spectroscopy،Vol. 2020, no. 2020, pp.1-6.
https://search.emarefa.net/detail/BIM-1190825

Modern Language Association (MLA)

Lomelí-Mejía, Pedro A.…[et al.]. Evaluation of Tensile Force in a Porcine Trachea Using a Reflective Optical Method. Journal of Spectroscopy No. 2020 (2020), pp.1-6.
https://search.emarefa.net/detail/BIM-1190825

American Medical Association (AMA)

Lomelí-Mejía, Pedro A.& Cruz-Orea, Alfredo& Araujo-Monsalvo, Víctor M.& López-Sánchez, Alberto& Huerta-Azuara, Andrés& Aguirre-Palomé, Crystal…[et al.]. Evaluation of Tensile Force in a Porcine Trachea Using a Reflective Optical Method. Journal of Spectroscopy. 2020. Vol. 2020, no. 2020, pp.1-6.
https://search.emarefa.net/detail/BIM-1190825

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1190825