![](/images/graphics-bg.png)
Structural design model and economic feasibility of using concrete filled glass fiber reinforced epoxy tube columns
Other Title(s)
نموذج التصميم الإنشائي والجدوى الاقتصادية لاستخدام أعمدة أنابيب الإيبوكسي المقواة بالألياف الزجاجية والمملوءة بالخرسانة
Author
Source
Journal of Al-Azhar University Engineering Sector
Issue
Vol. 17, Issue 65 (31 Oct. 2022), pp.1200-1220, 21 p.
Publisher
al-Azhar University Faculty of Engineering
Publication Date
2022-10-31
Country of Publication
Egypt
No. of Pages
21
Main Subjects
Topics
- Feasibility studies
- Structural design
- Pipes
- Reinforced concrete
- Economic aspects
- Glass fibers
- Concrete columns
- Epoxy Alloys
Abstract AR
يتطلب التصميم الإنشائي للأعمدة المكونة من أنابيب الإيبوكسي المقواة بالألياف الزجاجية والمملؤة بالخرسانة CFT تحديد السمك والمادة المناسبة لأنبوب الحصر.
ويعد الإيبوكسي المقوى بالألياف الزجاجية GFRE مادة مستدامة توفر مقاومة ضد الملح والكبريتات.
تم تصميم وتنفيذ برنامج تجريبي لأعمدة CFT الدائرية للتحقق من سهولة تطبيق مواصـفات الكود الأمريكي علي الخامات المحلية المتوافرة، والذي يتكون من ست عينات مقسمة إلى مجموعتين: أعمدة CFT مسلحة وأخري غير مسلحة، وكانت العوامل المدروسة هي: مقاومة الضغط لأعمدة CFT، الانفعال المحوري، الانفعال الدائري، ومنحنيات الحمل- الإجهاد، وسلوك انهيار العينات.
لقد وجد أن تلبية متطلبات الكود الأمريكي ACI يحقق تنبؤا متحفظا لمقاومة الضغط القصوى ل CFT وكذلك الانفعال المحوري للعينات بمتوسط عامل أمان يبلغ 2.15 في التنبؤ بمقاومة الانضغاط.
تم اقتراح نموذج تصميمي قابل للتطبيق بناءا على مواصفات الكود الأمريكي ACI 318 [3] وACI 440.02 [4]، موفرا تنبأ مسئول لمقاومة الانضغاط الخاصة بالخرسانة المحصورة وأخذا في الاعتبار تأثير حجم (قطر) أعمدة ال CFT أيضا، تم إجراء دراسة اقتصادية لاستخدام أعمدة CFT بناء على حجم الخرسانة المسلحة المماثلة لها لضمان جدواها الاقتصادية مقارنة بالأعمدة الخرسانية المسلحة التقليدية.
Abstract EN
Structural design of concrete filled tube CFT columns requires defining an appropriate thickness and material of confining tube.
the glass fiber reinforced epoxy GFRE is a sustain material that provides resistance against salt and sulphates.
experimental program of circular CFT columns was carried out to verify the applicability of the ACI provisions using available local materials, which consists of six specimens divided into two groups: reinforced and un-reinforced CFT columns, studied parameters were: compressive strength of CFT columns, axial strain, hoop strain, load–strain behavior, and failure behavior.
it was found that satisfying the ACI requirements achieves a conservative evaluation of CFT ultimate compressive strength and axial strain of concrete with average factor of safety of 2.15 in predicting compressive strength.
an applicable design model proposed depending on ACI 318 [3] and ACI 440.02 [4] specification, providing reasonable prediction of confined concrete strength ???′ and the size effect of CFT columns.
also, an economic study of using CFT columns based on volume of its peer reinforced concrete was made to assure its economic feasibility comparing to the traditional reinforced concrete columns.
American Psychological Association (APA)
Kottb, Hani Ali. 2022. Structural design model and economic feasibility of using concrete filled glass fiber reinforced epoxy tube columns. Journal of Al-Azhar University Engineering Sector،Vol. 17, no. 65, pp.1200-1220.
https://search.emarefa.net/detail/BIM-1426504
Modern Language Association (MLA)
Kottb, Hani Ali. Structural design model and economic feasibility of using concrete filled glass fiber reinforced epoxy tube columns. Journal of Al-Azhar University Engineering Sector Vol. 17, no. 65 (Oct. 2022), pp.1200-1220.
https://search.emarefa.net/detail/BIM-1426504
American Medical Association (AMA)
Kottb, Hani Ali. Structural design model and economic feasibility of using concrete filled glass fiber reinforced epoxy tube columns. Journal of Al-Azhar University Engineering Sector. 2022. Vol. 17, no. 65, pp.1200-1220.
https://search.emarefa.net/detail/BIM-1426504
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references: p. 1220
Record ID