Establishment of a Swine Model for Validation of Perfusion Measurement by Dynamic Contrast-Enhanced Magnetic Resonance Imaging

Joint Authors

Kramer, Martin
Hindel, Stefan
Wissmann, Andreas
Krüger, Christine
Sauerbrey, Anika
Nafz, Benno
Lüdemann, Lutz
Maaß, Marc

Source

BioMed Research International

Issue

Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-9, 9 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2014-02-27

Country of Publication

Egypt

No. of Pages

9

Main Subjects

Medicine

Abstract EN

The aim of the study was to develop a suitable animal model for validating dynamic contrast-enhanced magnetic resonance imaging perfusion measurements.

A total of 8 pigs were investigated by DCE-MRI.

Perfusion was determined on the hind leg musculature.

An ultrasound flow probe placed around the femoral artery provided flow measurements independent of MRI and served as the standard of reference.

Images were acquired on a 1.5 T MRI scanner using a 3D T1-weighted gradient-echo sequence.

An arterial catheter for local injection was implanted in the femoral artery.

Continuous injection of adenosine for vasodilation resulted in steady blood flow levels up to four times the baseline level.

In this way, three different stable perfusion levels were induced and measured.

A central venous catheter was used for injection of two different types of contrast media.

A low-molecular weight contrast medium and a blood pool contrast medium were used.

A total of 6 perfusion measurements were performed with a time interval of about 20–25 min without significant differences in the arterial input functions.

In conclusion the accuracy of DCE-MRI-based perfusion measurement can be validated by comparison of the integrated perfusion signal of the hind leg musculature with the blood flow values measured with the ultrasound flow probe around the femoral artery.

American Psychological Association (APA)

Sauerbrey, Anika& Hindel, Stefan& Maaß, Marc& Krüger, Christine& Wissmann, Andreas& Kramer, Martin…[et al.]. 2014. Establishment of a Swine Model for Validation of Perfusion Measurement by Dynamic Contrast-Enhanced Magnetic Resonance Imaging. BioMed Research International،Vol. 2014, no. 2014, pp.1-9.
https://search.emarefa.net/detail/BIM-468325

Modern Language Association (MLA)

Sauerbrey, Anika…[et al.]. Establishment of a Swine Model for Validation of Perfusion Measurement by Dynamic Contrast-Enhanced Magnetic Resonance Imaging. BioMed Research International No. 2014 (2014), pp.1-9.
https://search.emarefa.net/detail/BIM-468325

American Medical Association (AMA)

Sauerbrey, Anika& Hindel, Stefan& Maaß, Marc& Krüger, Christine& Wissmann, Andreas& Kramer, Martin…[et al.]. Establishment of a Swine Model for Validation of Perfusion Measurement by Dynamic Contrast-Enhanced Magnetic Resonance Imaging. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-9.
https://search.emarefa.net/detail/BIM-468325

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-468325