Comparison of the Tendon Damage Caused by Four Different Anchor Systems Used in Transtendon Rotator Cuff Repair
Joint Authors
O'Brien, Michael J.
Zhang, Qing-Song
Zhang, Qiuyang
Ge, Dongxia
You, Zongbing
Liu, Sen
Xue, Yun
Savoie, Felix H.
Source
Issue
Vol. 2012, Issue 2012 (31 Dec. 2012), pp.1-6, 6 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2012-07-01
Country of Publication
Egypt
No. of Pages
6
Main Subjects
Abstract EN
Objectives.
The objective of this study was to compare the damage to the rotator cuff tendons caused by four different anchor systems.
Methods.
20 cadaveric human shoulder joints were used for transtendon insertion of four anchor systems.
The Healix Peek, Fastin RC, Bio-Corkscrew Suture, and Healix Transtend anchors were inserted through the tendons using standard transtendon procedures.
The areas of tendon damage were measured.
Results.
The areas of tendon damage (mean ± standard deviation, n=7) were 29.1 ± 4.3 mm2 for the Healix Peek anchor, 20.4 ± 2.3 mm2 for the Fastin RC anchor, 23.4 ± 1.2 mm2 for the Bio-Corkscrew Suture anchor, 13.7 ± 3.2 mm2 for the Healix Transtend anchor inserted directly, and 9.1 ± 2.1 mm2 for the Healix Transtend anchor inserted through the Percannula system (P<0.001 or P<0.001, compared to other anchors).
Conclusions.
In a cadaver transtendon rotator cuff repair model, smaller anchors caused less damage to the tendon tissues.
The Healix Transtend implant system caused the least damage to the tendon tissues.
Our findings suggest that smaller anchors should be considered when performing transtendon procedures to repair partial rotator cuff tears.
American Psychological Association (APA)
Zhang, Qing-Song& Liu, Sen& Zhang, Qiuyang& Xue, Yun& Ge, Dongxia& O'Brien, Michael J.…[et al.]. 2012. Comparison of the Tendon Damage Caused by Four Different Anchor Systems Used in Transtendon Rotator Cuff Repair. Advances in Orthopedics،Vol. 2012, no. 2012, pp.1-6.
https://search.emarefa.net/detail/BIM-499044
Modern Language Association (MLA)
Zhang, Qing-Song…[et al.]. Comparison of the Tendon Damage Caused by Four Different Anchor Systems Used in Transtendon Rotator Cuff Repair. Advances in Orthopedics No. 2012 (2012), pp.1-6.
https://search.emarefa.net/detail/BIM-499044
American Medical Association (AMA)
Zhang, Qing-Song& Liu, Sen& Zhang, Qiuyang& Xue, Yun& Ge, Dongxia& O'Brien, Michael J.…[et al.]. Comparison of the Tendon Damage Caused by Four Different Anchor Systems Used in Transtendon Rotator Cuff Repair. Advances in Orthopedics. 2012. Vol. 2012, no. 2012, pp.1-6.
https://search.emarefa.net/detail/BIM-499044
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-499044