The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty

Joint Authors

Erickson, Jill
Peters, Christopher L.
Evans, David
Christensen, Bryt A.
Severson, Erik P.
Pelt, Christopher E.
Widmer, Benjamin

Source

BioMed Research International

Issue

Vol. 2014, Issue 2014 (31 Dec. 2014), pp.1-6, 6 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2014-05-14

Country of Publication

Egypt

No. of Pages

6

Main Subjects

Medicine

Abstract EN

Little data exists regarding outcomes following TKA performed with surface-cementation for the fixation of modular tibial baseplates with press-fit keels.

Thus, we retrospectively reviewed the clinical and radiographic outcomes of 439 consecutive primary TKAs performed with surface cemented tibial components.

There were 290 female patients and 149 male patients with average age of 62 years (range 30–84).

Two tibial components were revised for aseptic loosening (0.5%) and four tibial components (0.9%) were removed to improve instability (n=2) or malalignment (n=2).

Complications included 13 deep infections treated with 2-stage revision (12) and fusion (1).

These results support the surface cement technique with a modular grit-blasted titanium surface and cruciform stem during primary TKA.

American Psychological Association (APA)

Pelt, Christopher E.& Erickson, Jill& Christensen, Bryt A.& Widmer, Benjamin& Severson, Erik P.& Evans, David…[et al.]. 2014. The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty. BioMed Research International،Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-512572

Modern Language Association (MLA)

Pelt, Christopher E.…[et al.]. The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty. BioMed Research International No. 2014 (2014), pp.1-6.
https://search.emarefa.net/detail/BIM-512572

American Medical Association (AMA)

Pelt, Christopher E.& Erickson, Jill& Christensen, Bryt A.& Widmer, Benjamin& Severson, Erik P.& Evans, David…[et al.]. The Use of a Modular Titanium Baseplate with a Press-Fit Keel Implanted with a Surface Cementing Technique for Primary Total Knee Arthroplasty. BioMed Research International. 2014. Vol. 2014, no. 2014, pp.1-6.
https://search.emarefa.net/detail/BIM-512572

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-512572