Calculations of effective dose in diagnostic radiology
Joint Authors
Source
Sudan Journal of Basic Sciences. |n Series : Mathematical Science
Issue
Vol. 2012, Issue 17 (31 Dec. 2012), pp.121-134, 14 p.
Publisher
Sudan Institute for Natural Sciences Publication Unit
Publication Date
2012-12-31
Country of Publication
Sudan
No. of Pages
14
Main Subjects
Abstract EN
The study was performed to compare two methods used for effective dose (ED) calculations in diagnostic radiology and to evaluate the ED distribution in radiological departments in four major hospitals in Khartoum, Sudan.
Dosimetric data for six radiographic projections and a sample of 346 patients were used in the study.
First, ED was calculated from entrance skin dose using NRPB-SR262 Monte Carlo data.
Second, energy imparted () to each patient was estimated using entrance skin exposure, half value layer and the beam area at the entrance plane.
ED was then estimated using projection specific ED/ conversion factors.
Mean ED values calculated using the two methods were: 21.3-23.4, 14.1-12.8, 7.9-8.5, 232-226, 215-223 and 91-85.6 μSv for chest PA, Skull AP/PA, Skull LAT, Pelvis AP, Lumbar Spine AP and Lumbar Spine LAT examinations, respectively.
The values obtained are in good agreement between themselves and with data reported in the literature
American Psychological Association (APA)
Habbani, F. I.& Sulayman, I. I.. 2012. Calculations of effective dose in diagnostic radiology. Sudan Journal of Basic Sciences. |n Series : Mathematical Science،Vol. 2012, no. 17, pp.121-134.
https://search.emarefa.net/detail/BIM-754407
Modern Language Association (MLA)
Habbani, F. I.& Sulayman, I. I.. Calculations of effective dose in diagnostic radiology. Sudan Journal of Basic Sciences. |n Series : Mathematical Science No. 17 (2012), pp.121-134.
https://search.emarefa.net/detail/BIM-754407
American Medical Association (AMA)
Habbani, F. I.& Sulayman, I. I.. Calculations of effective dose in diagnostic radiology. Sudan Journal of Basic Sciences. |n Series : Mathematical Science. 2012. Vol. 2012, no. 17, pp.121-134.
https://search.emarefa.net/detail/BIM-754407
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references : p. 132-134
Record ID