Robust high resolution fat-water separation in the abdomen during free-breathing by self-gated 2D Radial TrueFISP imaging

Joint Authors

Ababinah, Riyad S.
Benkert, Thomas
Breuer, Felix A.

Source

Jordan Journal of Physics

Issue

Vol. 9, Issue 2 (31 Dec. 2016), pp.103-108, 6 p.

Publisher

Yarmouk University Deanship of Research and Graduate Studies

Publication Date

2016-12-31

Country of Publication

Jordan

No. of Pages

6

Main Subjects

Physics

Abstract EN

Accurate high resolution fat-water separation in the abdomen is challenging due to respiratory motion.

In this work, we propose a robust high resolution fat-water separation strategy in the abdomen during free breathing by employing radial sampling with a golden angle increment.

To this end, a radial TrueFISP sequence was modified enabling the echo time TE to change from projection to projection, to force fat signals to behave in a conspicuous manner through time, so that they can be detected and separated from water signals through temporal processing.

Thus, the center signal (DC) of each radial readout can then be used for respiratory gating, allowing the generation of multiple images at different TEs at multiple breathing states.

Finally, any fat-water separation technique can be used to synthesize high resolution fat and water images at arbitrary breathing states.

Good separation of fat and water signals was achieved using the radial TrueFISP sequence during free breathing without streaking artifacts or blurring due to respiratory motion.

American Psychological Association (APA)

Ababinah, Riyad S.& Benkert, Thomas& Breuer, Felix A.. 2016. Robust high resolution fat-water separation in the abdomen during free-breathing by self-gated 2D Radial TrueFISP imaging. Jordan Journal of Physics،Vol. 9, no. 2, pp.103-108.
https://search.emarefa.net/detail/BIM-818887

Modern Language Association (MLA)

Ababinah, Riyad S.…[et al.]. Robust high resolution fat-water separation in the abdomen during free-breathing by self-gated 2D Radial TrueFISP imaging. Jordan Journal of Physics Vol. 9, no. 2 (2016), pp.103-108.
https://search.emarefa.net/detail/BIM-818887

American Medical Association (AMA)

Ababinah, Riyad S.& Benkert, Thomas& Breuer, Felix A.. Robust high resolution fat-water separation in the abdomen during free-breathing by self-gated 2D Radial TrueFISP imaging. Jordan Journal of Physics. 2016. Vol. 9, no. 2, pp.103-108.
https://search.emarefa.net/detail/BIM-818887

Data Type

Journal Articles

Language

English

Record ID

BIM-818887